< Page:Radio-activity.djvu
This page needs to be proofread.

The second column gives the observed activity (measured by

means of an electroscope) for a long exposure of 24 hours in the presence of the emanation.

In cases where a steady current of air is drawn over the active body, the observed values are slightly lower than the theoretical. This is probably due to a slight volatility of the product radium B at ordinary temperatures.

Fig. 90.


223. Analysis of the α-ray curves. The analysis of the decay curves of the excited activity of radium, measured by the α rays, will now be discussed. The following table shows the variation of the intensity of the radiation after a long exposure in the presence of the radium emanation. A platinum plate was made active by exposure for several days in a glass tube containing a large quantity of emanation. The active platinum after removal was placed on the lower of two parallel insulated lead plates, and a saturating electromotive force of 600 volts was applied. The ionization current was sufficiently large to be measured by means of a sensitive high-resistance galvanometer, and readings were taken as quickly as possible after removal of the platinum from the emanation vessel. The initial value of the current (taken